CLINICAL CASE Missing Teeth #15(4) & #16(3) 6 mm Sub Sinus Bone Height Dr. David Baranes DMD, IsraelPre-Op CBCTPre-Op CBCTInitial AspectFull Thickness FlapB.Y.S. 5B.Y.S 6 – The B.Y.S.6 fractured the sinus floor, bony disk surrounded by bleeding membrane.Bleeding MembraneMembrane Elevation – The membrane elevation by osteotome 7mm, 8mm, 9mm, 10mm, 11mm , 1 mm by 1 mm.Bleeding – Bleeding is a sign of an intact membrane.Placing Bond Apatite® – The syringe deposits the bone graft at the opening.Osteotome – 6 mm – The 6mm osteotome is used to introduce the graft into the sinus. Repeat the process of adding Bond Apatite® and placing it in the sinus 5 times. With each application lower the osteotome 1mm. [9mm, 8mm, 7mm, 6mm]Implant in PlaceSuturesFinal Results